Bảng đèn của Server IBM 3650
Nội dung bên dưới cho biết ý nghĩa của các đèn báo trong bảng đèn của server. Và các việc cần kiểm tra trên server.
|
||
---|---|---|
LED | Description | Action |
Check log LED | An error has occurred and cannot be isolated without performing certain procedures. |
|
System-error LED | An error has occurred. |
|
PS | When only the PS LED is lit, a power supply has failed. |
The system might detect a power supply error. Complete the following steps to correct the problem:
|
PS + CONFIG When both the PS and CONFIG LEDs are lit, the power supply configuration is invalid. |
If the PS LED and the CONFIG LED are lit, the system issues an invalid power configuration error. Make sure that both power supplies installed in the server are of the same rating or wattage.
|
|
OVER SPEC | The system consumption reaches the power supply over-current protection point or the power supplies are damaged. |
|
PCI | An error has occurred on a PCI card, a PCI bus, or on the system board. An additional LED is lit next to a failing PCI slot. |
|
NMI | A nonmaskable interrupt has occurred, or the NMI button was pressed. |
|
CONFIG | CONFIG + PS An invalid power configuration error has occurred. |
If the CONFIG LED and the PS LED are lit, the system issues an invalid power configuration error. Make sure that both power supplies installed in the server are of the same rating or wattage.
|
CONFIG + CPU A hardware configuration error has occurred. |
If the CONFIG LED and the CPU LED are lit, complete the following steps to correct the problem:
|
|
CONFIG + MEM A hardware configuration error has occurred. |
If the CONFIG LED and the MEM LED are lit, check the system-event log in the Setup utility or IMM2 error messages. Follow steps indicated in UEFI/POST diagnostic codes and Integrated management module II (IMM2) error messages.
|
|
LINK | Reserved. | |
CPU | When only the CPU LED is lit, a microprocessor has failed. |
If the CONFIG LED is not lit, a microprocessor failure occurs, complete the following steps:
|
CPU + CONFIG When both the CPU LED and the CONFIG LED are lit, the microprocessor configuration is invalid. |
If the CONFIG LED and the CPU LED are lit, the system issues an invalid microprocessor configuration error. Complete the following steps to correct the problem:
|
|
MEM | When only the MEM LED is lit, a memory error has occurred. |
Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
If the CONFIG LED is not lit, the system might detect a memory error. Complete the following steps to correct the problem:
|
MEM + CONFIG When both the MEM and CONFIG LEDs are lit, the memory configuration is invalid. |
If the MEM LED and the CONFIG LED are lit, check the system-event log in the Setup utility or IMM2 error messages. Follow steps indicated in UEFI/POST diagnostic codes and Integrated management module II (IMM2) error messages.
|
|
TEMP | The system or the system component temperature has exceeded a threshold level. A failing fan can cause the TEMP LED to be lit. |
|
FAN | A fan has failed, is operating too slowly, or has been removed. The TEMP LED might also be lit. |
|
BOARD | An error has occurred on the system board or the system battery. |
|
HDD | A hard disk drive has failed or is missing. |
|