Máy đo độ cứng cầm tay Phase II PHT-1800

Liên hệ

Máy đo độ cứng cầm tay Phase II PHT-1800 Máy đo độ cứng cầm tay… Xem thêm

Mua hàng
Từ khóa:
Thông tin chi tiết

Máy đo độ cứng cầm tay Phase II PHT-1800

Máy đo độ cứng cầm tay Phase II PHT-1800

Hãng sản xuất: Phase II – USA

Model: PHT-1800

Operation:
• Load the impact body
• Place the impact body on your test piece
• Push the button to begin testing and obtain reading

Standard Accessories:
• Base instrument
• Impact device D
• Calibrated test block
• Custom carry case
• Cleaning brush
• Operation manual

Optional accessories:
• Impact devices; DC, D+15, DL, G, C
• Special support rings

Functions:
• Easy to use keypad operation
• Auto identification of Impact Device
• Large LCD display with back light
• USB Ouput
• Automatic conversions to: Brinell, Rockwell B & C, Vicker and Shore
• Automatic mean value as well as Min & Max values
• Battery Indicator
• Memory capacity (100 groups)

Specifications:
• Accuracy: +/- 0.5% (referred to L=800,
• Repeatability accuracy: +/- 4L units) L=Leeb
• Measuring range: 200-960 HL
• Materials: steel & cast steel, alloy tool steel, stainless steel, grey cast iron,
• spheroidal iron, cast aluminum, brass, bronze, wrought copper alloy.
• Battery type: AA alkaline (4)
• Operating temperature: 5-104 degrees F
• Dimensions: 150 x 74 x 32mm
• Weight: 245 grams

mpact Device D
Universal standard device:
Use for the majority of hardness testing assignments
Impact Device DL (not shown)
Needle front section .109” diameter x 1.96” length
Measurements in extremely confined spaces
Impact Device G
Enlarged test tip: For use on solid heavy components such as; rough castings and forgings. Brinell only.
Impact Device DC
Extremely short impact device
Used for very confined spaces such as holes, cylinders, internal measurements
Impact Device D+15
Slim front section with coil set back.
Hardness measurements in grooves, recessed surface.
Impact Device C
Reduced impact energy
For testing case hardened or thin walled components

 
Impact Device Specifications for PHT-1800

 

Impact devices D/DC/DL D+15 C G
Impact energy 11Nmm 11Nmm 3Nmm 90Nmm
Mass of the impact body 5.5g 7.8g 3.0g 20g
  DL: 7.2g      
Test tip        
* Hardness 1600HV 1600HV 1600HV 1600HV
* Diameter 3mm 3mm 3mm 5mm
* Material   Tungsten Tungsten  
*   carbide carbide  
Impact device        
* Diameter 20mm 20mm 20mm 30mm
* Length 147/86mm 162mm 141mm 254mm
* Weight 75/50g 80g 75g 250g
Max. hardness of sample 940HV 940HV 1000HV 650HB
Preparation of surface        
* Max. roughness depth Rt 10 m m 10 m m 2.5 m m 30 m m
* Average roughness Ra 2 m m 2 m m 0.4 m m 6.3 m m
Min. weight of sample        
* Of compact shape 5kg 5kg 1.5kg 15kg
* On solid support 2kg 2kg 0.5kg 5kg
* Coupled on plate 0.  1kg 0.  1kg 0.  02kg 0.  5kg
Min. thickness of sample        
* Coupled 3mm 3mm 1mm 10mm
* Min. thickness of layers 0.  8mm 0.  8mm 0.  2mm    –
Indentation of test tip        
With 300 HV        
* Diameter 0.  54mm 0.  54mm 0.  38mm 1.03mm
* Depth 24 m m 24 m m 12 m m 53 m m
with 600 HV        
* Diameter 0.  45mm 0.  45mm 0.  32mm 0.  90mm
* Depth 17 m m 17 m m 8 m m 41 m m
with 800 HV        
* Diameter 0.  35mm 0.  35mm 0.  30mm    –
* Depth 10 m m 10 m m 7 m m    –

SUPPORT RINGS: We offer a 12pc set of rings for testing concave or convex parts.

máy đo độ cứng kim loại Phase II

Phụ kiện chuẩn bao gồm:

• Base instrument

• Impact device D

• Calibrated test block

• Custom carry case

• Cleaning brush

• Operation manual